276°
Posted 20 hours ago

Honeywell V4043H 1056 2 Port Zone Valve Normally Closed 22mm

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

The wires to disconnect are the two wires which run from the motor. On earlier motorised valves, these were both joined to other wires using metal crimps encased in plastic. On more recent valves, one wire is joined with a crimp and the other is wired directly to the electrical components of the valve. The Honeywell V4073A 3-port valve has five wires. These are blue, green/yellow, white, grey and orange. Note that the grey and orange wires are used differently from the grey and orange wires of the 2-port valve! However, if you need to replace the motor it may be easier to remove the powerhead so you can work on it in the open. Remember, on early Honeywell motorised valves (pre-1985) you can’t remove the powerhead without draining down first!

Honeywell V4043H 1056 - 2 Port Motorised Zone Valve 22mm Honeywell V4043H 1056 - 2 Port Motorised Zone Valve 22mm

Much of what we describe also applies to ACL Drayton motorised valves like the Drayton 2-port ZA5/679-2 22mm zone valve and the Drayton 3-port MA1/679 22mm mid-position valve. Iflo motorised valves and British Gas motorised valves have similar faults. It may also apply to the Tower VAL222MV motorised valve, the Siemens CZV222 motorised valve and the Flomasta 27900SX motorised valve. The Honeywell V4043H1106 28mm 2-port zone valve has 6 wires. Five of these wires are the same as 22mm 2-port valve.Green/yellow is Earth, blue is Neutral, brown is Live (or Line) to the motor, grey and orange are connected to the end switch and form part of a separate circuit. A normally-closed valve is closed when no power is being applied to it and needs electrical power to drive it open.The rubber ball sits against the circular port (right side in photo), closing it off. We’re told that the ball touches one edge of the circular port first, causing the ball to rotate slightly on its spindle. This regular slight rotation evens out distortions in the ball. A little piece of elegant design work by Honeywell!

Honeywell Home 22mm 2 Port Motorised Valve (V4043H1056/U) - CEF

If, for example, the heating valve is failing in this way, you will get heat round the radiators while the cylinder hot water is being heated too. When the cylinder is up to temperature, the hot water motorised valve closes and no longer tells the boiler to fire, so the heating now stops too. It may be easier to have the valve set in the manually open position using the manual lever. (See Honeywell Motorised Valve Manual Lever, below.) When a V4073A mid-position valve is set up in a Y-Plan configuration and Hot Water is called for, power to the boiler is provided directly from the cylinder thermostat. The valve is not energised. Starting with the controls set for Heating Only, hold the lever tight against the right side of the slot. Now get someone to select Hot Water too, so you get Heating and Hot Water together. You may need to turn the cylinder stat up to make it call. As soon as Hot Water is also called, you will hearthe valve start to unwind under the force of the spring, then you will feel the lever “bump” your finger. V4043H1056 is a 2 port, 22mm compression, 5-wire, normally-closed zone valve with an auxiliary end switch

Where two 2-port motorised valves are fitted (one for the heating circuit and one for the hot water cylinder circuit) the fault may be disguised. Even though one valve only partly opens itself and is unable to fire the boiler, the valve on the other circuit can open fully and fire the boiler. The pump then pushes heated boiler water through both the open valve and the partially open valve. The auxiliary circuit (grey and orange wires) is commonly used to operate the boiler and/or the circulating pump. The auxiliary circuit could be set to work at a lower voltage than mains but it is normally carrying mains voltage. It works like this: One of the two wires, typically the grey, is connected to a permanent mains Live supply (about 230V AC in the UK). The other wire, usually the orange, is connected to the Switched Live feed to the boiler. Sometimes a powerhead is able to drive the valve only part way open but not far enough for the auxiliary circuit end switch to close. This valve will then not be able to tell the boiler to fire. Seized motorised valve spindle in an old Satchwell Sunvic 2-port motorised valve. The water leakage has caused white oxides to form round the brass spindle, making it too stiff to turn The Honeywell mid-position motorised valve has three ports in a T configuration. Water enters via port AB. Water leaves by either port A or port B or by both at the same time. Port A is normally connected to the radiator circuit and Port B to the cylinder coil (to heat hot water). The circulating pump is usually connected to feed water from the boiler into port AB.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment